Our own factory, plus a partner ecosystem: catalogue sizes for standard parts, your drawing for custom parts.

Send your drawing or spec list →

ENGINEERING TOOL

M6 Bolt Torque Chart: Specs, Values & Settings

Class 8.8 · Target preload (kN) 9

Dry / Black11 N·m
10–12
Electro Zinc9 N·m
8–11
Hot-Dip Galv.12 N·m
10–14
Oiled7 N·m
6–8

M6 bolt torque spec: class 8.8 dry is 11 N·m (8 ft·lb). Values cover six property classes across five friction states — dry, zinc, HDG, oiled and anti-seize. K-factor method, basis fully disclosed.

Full PDF

Download the full PDF (M6–M36, all sizes)

Printable chart covering every size in this family — enter your email to get it.

Other sizes

Torque by Property Class and Friction State

Quick answer: class 8.8 · dry / black ≈ 11 N·m (10–12); other classes and friction states below.

ClassRp0.2 (MPa)Target preload (kN)Dry / Black
K 0.18–0.22 · N·m
Electro Zinc
K 0.15–0.2 · N·m
Hot-Dip Galv.
K 0.18–0.25 · N·m
Oiled
K 0.12–0.15 · N·m
Wax / PTFE / Anti-seize
K 0.08–0.12 · N·m
4.83404.86
5–6
5
4–6
6
5–7
4
3–4
3
2–3
8.8640911
10–12
9
8–11
12
10–14
7
6–8
5
4–6
10.994013.216
14–17
13
12–16
17
14–20
10
10–12
8
6–10
12.9110015.519
17–20
16
14–19
20
17–23
12
11–14
9
7–11
A2-704506.38
7–8
6
6–8
8
7–9
5
5–6
4
3–5
A4-806008.410
9–11
9
8–10
11
9–13
7
6–8
5
4–6

Cell shows the typical value; the small line below is the range (min–max).

Fine-Thread Torque Matrix

Fine-thread series (M6 × 1 mm) target preload and tightening torque ranges, same basis as the coarse chart; the fine-thread stress area As follows ISO 898-1:2013 Table 6 (this page takes M6 As = 20.1 mm²).

M6 is not covered by the fine-thread stress area table of ISO 898-1:2013 (Table 6 starts at M8×1); the fine-thread values shown on this page equal the coarse chart.

ClassRp0.2 (MPa)Target preload (kN)Dry / Black
K 0.18–0.22 · N·m
Electro Zinc
K 0.15–0.2 · N·m
Hot-Dip Galv.
K 0.18–0.25 · N·m
Oiled
K 0.12–0.15 · N·m
Wax / PTFE / Anti-seize
K 0.08–0.12 · N·m
4.83404.86
5–6
5
4–6
6
5–7
4
3–4
3
2–3
8.8640911
10–12
9
8–11
12
10–14
7
6–8
5
4–6
10.994013.216
14–17
13
12–16
17
14–20
10
10–12
8
6–10
12.9110015.519
17–20
16
14–19
20
17–23
12
11–14
9
7–11
A2-704506.38
7–8
6
6–8
8
7–9
5
5–6
4
3–5
A4-806008.410
9–11
9
8–10
11
9–13
7
6–8
5
4–6

Cell shows the typical value; the small line below is the range (min–max).

Basis of Calculation & Sources

Calculation basis

  • Torque follows the K-factor (nut factor) method T = K·D·F: D is the nominal diameter and F the target preload = 70% of Rp0.2 × thread stress area (M6 As = 20.1 mm²).
  • Yield strengths are published values from ISO 898-1 (carbon/alloy steel) and ISO 3506-1 (stainless A2/A4).
  • K follows published empirical ranges per friction condition (Machinery's Handbook; the wax/PTFE/anti-seize band K≈0.10 follows Machine Design test data).
  • The grease/MoS₂ band (K≈0.11) nearly overlaps anti-seize and is available in the calculator instead of a separate column.

Stainless note: A2/A4 austenitic thread pairs gall easily under frictional heating. Always apply anti-seize and follow the Wax/PTFE/Anti-seize column (K≈0.10).

Scope & limits

  • This chart is a simplified K-factor estimate, not a full VDI 2230 analysis (which accounts for joint resilience, embedment and assembly method).
  • Friction is the dominant variable — no single torque value exists without its friction state.
  • Always follow the design specification or manufacturer torque table.

Cite this chart

YAXIIO. M6 Bolt Torque Chart: Specs, Values & Settings. https://www.yaxiio.com/en/tools/bolt-torque-chart/m6 (accessed 2026-10-29).

Free to cite and embed — attribution required: “YAXIIO” + a link to this page.

FAQ

What is the target preload for an M6 bolt?

At 70% of Rp0.2: class 4.8 ≈ 4.8 kN, 8.8 ≈ 9 kN, 10.9 ≈ 13.2 kN; stainless A2-70 ≈ 6.3 kN and A4-80 ≈ 8.4 kN.

Can I use carbon-steel torque values for stainless M6 (A2-70/A4-80)?

No. The classes have different yield strengths (A2-70 = 450 MPa, A4-80 = 600 MPa), so target preloads differ; and stainless thread pairs gall easily — always apply anti-seize and follow the Wax/PTFE/Anti-seize column (K≈0.10).

Related References

Disclaimer: This chart is an engineering estimation for selection and budgeting only. It does not constitute assembly instructions or acceptance criteria.