Engineering reference on fasteners and hardware, written by a team with manufacturing backgrounds.

About this site →

ENGINEERING TOOL

Bolt Torque Chart — Metric M6–M36 and Inch (SAE) 1/4″–2″

Inch (SAE Grade 2/5/8, 1/4″–2″ UNC) and metric (4.8–A4-80, M6–M36) torque tables on one page, on the same K-factor basis and the same target-preload convention, with the nearest metric size of every inch size in the same row. Every number here can be recomputed from the formula and the friction range shown below.

Full PDF

Download the full PDF (M6–M36 / 1/4"–2", all sizes)

Printable chart covering every size in this family — enter your email to get it.

Quick answer

Looking for one size only? Inch sizes 1/4″–2″ are in the first table, metric sizes M6–M36 in the second, and every size name links to its own page with five friction states, UNC and UNF.

1/2"-13 Grade 5 · dry / black (75% of proof stress) ≈ 102 N·m (92–112 N·m) · 75.2 ft·lb.

M12 class 8.8 · dry / black (70% of Rp0.2) ≈ 91 N·m (82–100 N·m) · 67.1 ft·lb.

Both lines give the typical value with its range in brackets. The range is the friction coefficient K — a band, not a point (see the K table below).

Inch (SAE) Bolt Torque — 1/4″ to 2″

UNC coarse series; typical torque at 75% of the SAE J429 proof stress with dry / black friction (K 0.18–0.22). The small line under each cell is the range across that K band.

Inch sizeNearest metricGrade 2
N·m
Grade 5
N·m
Grade 8
N·m
1/4"UNC 20 · At 21 mm²M67N·m (5.2 ft·lb)
7–8
11N·m (8.1 ft·lb)
10–13
16N·m (11.8 ft·lb)
15–18
5/16"UNC 18 · At 34 mm²M815N·m (11.1 ft·lb)
14–17
24N·m (17.7 ft·lb)
21–26
33N·m (24.3 ft·lb)
30–37
3/8"UNC 16 · At 50 mm²M1027N·m (19.9 ft·lb)
24–30
42N·m (31 ft·lb)
38–46
59N·m (43.5 ft·lb)
53–65
7/16"UNC 14 · At 69 mm²M1243N·m (31.7 ft·lb)
39–48
67N·m (49.4 ft·lb)
60–74
95N·m (70.1 ft·lb)
85–104
1/2"UNC 13 · At 92 mm²M1266N·m (48.7 ft·lb)
60–73
102N·m (75.2 ft·lb)
92–112
144N·m (106 ft·lb)
130–159
9/16"UNC 12 · At 117 mm²M1495N·m (70.1 ft·lb)
86–105
148N·m (109 ft·lb)
133–162
208N·m (153 ft·lb)
187–229
5/8"UNC 11 · At 146 mm²M16132N·m (97.4 ft·lb)
119–145
204N·m (150 ft·lb)
183–224
288N·m (212 ft·lb)
259–316
3/4"UNC 10 · At 216 mm²M20234N·m (173 ft·lb)
210–257
361N·m (266 ft·lb)
325–397
510N·m (376 ft·lb)
459–561
7/8"UNC 9 · At 298 mm²M22226N·m (167 ft·lb)
204–249
582N·m (429 ft·lb)
524–641
822N·m (606 ft·lb)
740–904
1"UNC 8 · At 391 mm²M24339N·m (250 ft·lb)
305–373
873N·m (644 ft·lb)
785–960
1232N·m (909 ft·lb)
1109–1355
1-1/8"UNC 7 · At 493 mm²M30481N·m (355 ft·lb)
432–529
1078N·m (795 ft·lb)
970–1185
1747N·m (1289 ft·lb)
1573–1922
1-1/4"UNC 7 · At 625 mm²M33677N·m (499 ft·lb)
610–745
1519N·m (1120 ft·lb)
1367–1671
2464N·m (1817 ft·lb)
2217–2710
1-1/2"UNC 6 · At 907 mm²M361179N·m (870 ft·lb)
1061–1297
2644N·m (1950 ft·lb)
2379–2908
4287N·m (3162 ft·lb)
3858–4716
2"UNC 4.5 · At 1612 mm²—2794N·m (2061 ft·lb)
2515–3074
6266N·m (4622 ft·lb)
5640–6893
7621N·m (5621 ft·lb)
6859–8383

Cell shows the typical value with the other unit in brackets; the small line below is the range (min–max).

The nearest metric column is an order-of-magnitude comparison, not an equivalence: the two systems specify different diameters and thread forms, so a torque value must not be carried from one column to the other.

Metric Bolt Torque — M6 to M36

Typical torque at 70% of Rp0.2 with dry / black friction (K 0.18–0.22). The small line under each cell is the range across that K band.

Metric size4.8
N·m
8.8
N·m
10.9
N·m
12.9
N·m
A2-70
N·m
A4-80
N·m
M6As 20.1 mm²6N·m (4.4 ft·lb)
5–6
11N·m (8.1 ft·lb)
10–12
16N·m (11.8 ft·lb)
14–17
19N·m (14 ft·lb)
17–20
8N·m (5.9 ft·lb)
7–8
10N·m (7.4 ft·lb)
9–11
M8As 36.6 mm²14N·m (10.3 ft·lb)
13–15
26N·m (19.2 ft·lb)
24–29
39N·m (28.8 ft·lb)
35–42
45N·m (33.2 ft·lb)
41–50
18N·m (13.3 ft·lb)
17–20
25N·m (18.4 ft·lb)
22–27
M10As 58 mm²28N·m (20.7 ft·lb)
25–30
52N·m (38.4 ft·lb)
47–57
76N·m (56.1 ft·lb)
69–84
89N·m (65.6 ft·lb)
80–98
37N·m (27.3 ft·lb)
33–40
49N·m (36.1 ft·lb)
44–54
M12As 84.3 mm²48N·m (35.4 ft·lb)
43–53
91N·m (67.1 ft·lb)
82–100
133N·m (98.1 ft·lb)
120–146
156N·m (115 ft·lb)
140–171
64N·m (47.2 ft·lb)
57–70
85N·m (62.7 ft·lb)
76–93
M14As 115 mm²77N·m (56.8 ft·lb)
69–84
144N·m (106 ft·lb)
130–159
212N·m (156 ft·lb)
191–233
248N·m (183 ft·lb)
223–273
101N·m (74.5 ft·lb)
91–112
135N·m (99.6 ft·lb)
122–149
M16As 157 mm²120N·m (88.5 ft·lb)
108–132
225N·m (166 ft·lb)
203–248
331N·m (244 ft·lb)
298–364
387N·m (285 ft·lb)
348–426
158N·m (117 ft·lb)
142–174
211N·m (156 ft·lb)
190–232
M18As 192 mm²165N·m (122 ft·lb)
148–181
310N·m (229 ft·lb)
279–341
455N·m (336 ft·lb)
409–500
532N·m (392 ft·lb)
479–585
218N·m (161 ft·lb)
196–240
290N·m (214 ft·lb)
261–319
M20As 245 mm²233N·m (172 ft·lb)
210–257
439N·m (324 ft·lb)
395–483
645N·m (476 ft·lb)
580–709
755N·m (557 ft·lb)
679–830
309N·m (228 ft·lb)
278–340
412N·m (304 ft·lb)
370–453
M22As 303 mm²317N·m (234 ft·lb)
286–349
597N·m (440 ft·lb)
538–657
877N·m (647 ft·lb)
790–965
1027N·m (757 ft·lb)
924–1129
420N·m (310 ft·lb)
378–462
560N·m (413 ft·lb)
504–616
M24As 353 mm²403N·m (297 ft·lb)
363–444
759N·m (560 ft·lb)
683–835
1115N·m (822 ft·lb)
1003–1226
1305N·m (963 ft·lb)
1174–1435
534N·m (394 ft·lb)
480–587
712N·m (525 ft·lb)
640–783
M27As 459 mm²590N·m (435 ft·lb)
531–649
1110N·m (819 ft·lb)
999–1221
1631N·m (1203 ft·lb)
1468–1794
1909N·m (1408 ft·lb)
1718–2099
781N·m (576 ft·lb)
703–859
1041N·m (768 ft·lb)
937–1145
M30As 561 mm²801N·m (591 ft·lb)
721–881
1508N·m (1112 ft·lb)
1357–1659
2215N·m (1634 ft·lb)
1993–2436
2592N·m (1912 ft·lb)
2333–2851
1060N·m (782 ft·lb)
954–1166
1414N·m (1043 ft·lb)
1272–1555
M33As 694 mm²1090N·m (804 ft·lb)
981–1199
2052N·m (1513 ft·lb)
1847–2257
3014N·m (2223 ft·lb)
2713–3315
3527N·m (2601 ft·lb)
3174–3880
1443N·m (1064 ft·lb)
1299–1587
1924N·m (1419 ft·lb)
1731–2116
M36As 817 mm²1400N·m (1033 ft·lb)
1260–1540
2635N·m (1943 ft·lb)
2372–2899
3871N·m (2855 ft·lb)
3484–4258
4529N·m (3340 ft·lb)
4077–4982
1853N·m (1367 ft·lb)
1668–2038
2471N·m (1823 ft·lb)
2224–2718

Cell shows the typical value with the other unit in brackets; the small line below is the range (min–max).

Class 8.8 is the usual default for general connections. A2-70 and A4-80 are stainless and gall easily, so use the anti-seize friction band (K≈0.10) rather than the dry / black values shown here.

Grades, Preload Levels and Friction

The two tables above hold one friction state fixed so that inch and metric can be read side by side. Everything that moves a torque value — property class, preload level and friction — is disclosed here.

SAE Grade ↔ ISO Property Class

SAE J429Approx. ISO 898-1
Grade 24.8
Grade 58.8
Grade 810.9

Approximate only: the proof stresses are not equal even where the strength bands line up (Grade 5 sits near ISO 8.8, but each standard publishes its own proof value).

75% vs 90% of Proof Stress (Inch) · 70% of Rp0.2 (Metric)

Two preload levels are in common use. The standard level — 75% of the SAE J429 proof stress for inch sizes, 70% of Rp0.2 for metric classes — is reusable and can be re-torqued. The 90% proof level sits close to yield and is a one-time setting for permanent joints with a controlled assembly method. Both percentages are of the proof (or yield) stress, not of the tensile strength, and each size page shows both levels for its own size.

Nut Factor K — Six Friction States, Full Range

K is the nut factor in T = K · d · F. It is an empirical band rather than a constant: the same bolt reaches the same preload at a different torque depending on coating, lubrication, washers and reuse. The values below are the ranges this site uses everywhere.

Friction stateK minK typK max
Dry / Black0.180.20.22
Electro zinc0.150.170.2
Hot-dip galvanized0.180.220.25
Oiled0.120.130.15
Greased / MoS₂0.10.110.12
Wax / PTFE / Anti-seize0.080.10.12

To move between friction states, scale the torque by the ratio of the K values — the preload stays the same. The dry / black row is the one used in the two tables above. A single precise K can only come from testing the production coating, lubrication and washer stack.

Fine Threads (UNF) and the Missing Series

Both tables above are UNC coarse threads. UNF fine-thread values are on each size page, calculated independently from the same formula: a finer thread leaves more metal at the minor diameter, so the stress area and the torque at the same grade are higher. 2" has no UNF series in ASME B1.1 (the fine series stops at 1-1/2″), so that size page shows UNC only — a UNF column there would silently reuse the coarse pitch.

Calculation basis

  • T = K · d · F. F is the target preload: 75% of the SAE J429 proof stress for inch sizes (proof stress per the published J429 values, which step down by nominal-diameter tier) and 70% of Rp0.2 for metric classes (ISO 898-1 for carbon and alloy steel, ISO 3506-1 for A2/A4).
  • The inch stress area follows At = π/4·(d − 0.9743/n)² (ASME B1.1); metric uses As per ISO 898-1.
  • Each size name carries its own stress area, so any cell above can be recomputed from the formula and the K table.

Scope & limits

  • These are simplified K-factor estimates, not a full VDI 2230 analysis (joint resilience, embedment and assembly method are not modelled).
  • Friction is the dominant variable — no single torque value exists for a size without its friction state.
  • Production joints follow the design specification or the manufacturer's torque table.

References

Cite this chart

YAXIIO. Bolt Torque Chart — Metric M6–M36 and Inch (SAE) 1/4″–2″. https://www.yaxiio.com/en/tools/bolt-torque-chart (accessed 2026-11-17).

Free to cite and embed — attribution required: “YAXIIO” + a link to this page.

FAQ

Why is every value given as a range instead of one number?

Because K itself is a range: 102 N·m (92–112 N·m) · 75.2 ft·lb covers K 0.18–0.22 at one and the same target preload. Any single recommended torque figure implies one friction state, and that state is what has to be fixed first.

Do these tables cover UNC and UNF?

They cover UNC coarse threads for all 14 inch sizes; UNF fine-thread values are on each size page. 2" has no UNF series in ASME B1.1, so that page shows UNC only.

Related References

Disclaimer: these tables are an engineering estimation for selection and budgeting only. They do not constitute assembly instructions or acceptance criteria.