NPT 1/2 Tap Drill: 45/64 Direct, 11/16 Reamed

The answer for NPT 1/2, three ways

Drill and tap directly

45/64

0.703 in

Drill then ream

11/16

0.688 in

Straight NPSC reference

23/32

0.719 in

Direct drilling and reaming are the two methods printed in H28 Table 7.2; the straight NPSC value is the reference column that most modern charts publish. All three are shown because the chart you were given may quote any one of them.

NPT 1/2 · 0.84 in OD · 14 TPI

The common modern chart quotes 23/32 for this size; it is the straight column value.

Full pipe thread chart

Full PDF

Download the full PDF (1/16–2-1/2, all sizes)

Printable chart covering every size in this family — enter your email to get it.

NPT / NPTF tap drills (60° tapered pipe thread)

Both suggested drills from NBS Handbook H28 (1957) Part II, Table 7.2 are here as two tabs, and the straight NPSC column is carried in both so you can compare against any chart you already have. The tab you pick changes one column, not the page.

Drill the suggested straight hole and cut the taper with the pipe tap. This is how most pipe threads are run on the shop floor, and it is the method column H28 prints for use without a reamer.

NPT sizeTPIDrill — this methodStraight NPSC referenceCommon modern chart
1/1627D (0.246)1/4 (0.25)—
1/827Q (0.332)11/32 (0.344)R*
1/4187/16 (0.438)7/16 (0.438)7/16
3/81837/64 (0.578)37/64 (0.578)37/64
1/21445/64 (0.703)23/32 (0.719)23/32
3/41429/32 (0.906)59/64 (0.922)59/64
111.51-9/64 (1.141)1-5/32 (1.156)1-5/32
1-1/411.51-31/64 (1.484)1-1/2 (1.5)1-1/2
1-1/211.51-47/64 (1.734)1-3/4 (1.75)1-47/64*
211.52-13/64 (2.203)2-7/32 (2.219)2-7/32
2-1/282-5/8 (2.625)2-21/32 (2.656)2-5/8*

Values in the method column are the suggested twist drills printed in H28 Table 7.2 for that tapping method. The straight column is column 4 of the same table, the straight pipe thread (NPSC) size, not a third method.

Two methods, one page: direct drilling is the everyday route and reaming is the finishing route. Neither is a more standard answer than the other; the difference between the two columns is one drill step at every size in the table.

Most modern NPT charts publish the straight column. On this table the common chart agrees with the straight reference at 7 of the 10 sizes where it gives a value; the starred sizes (1/8, 1-1/2, 2-1/2) differ by one drill step, which is why the two usually quoted numbers for NPT tap drills are this straight value and the direct-drilling value one step below it.

Sizes above 2-1/2 in are not listed: the 1957 H28 table stops there, and no public-domain suggested drill is available for larger NPT sizes.

NPT and BSPP are not interchangeable

NPT has a 60° thread form with a 1:16 taper and seals on the threads; BSPP has a 55° form and is parallel, sealing on a washer or an O-ring. At most nominal sizes the threads per inch differ as well, so a NPT fitting will not seal in a BSPP port even where the thread starts. Check the callout before you drill either one.

Basis and how to use this chart

  • These are workshop guidance values, not mandatory dimensions. Material, tap condition, hole depth and lubrication all move the result, and a critical thread should be checked with the thread gauge named on the drawing.
  • NPT values are the suggested twist drills from NBS Handbook H28 (1957) Part II, Table 7.2, a US Government publication in the public domain. Both tapping methods and the straight reference are printed there, which is why this page shows all three.
  • BSPP basic dimensions (major, minor, pitch) are from GB/T 7307-2001; the tap drill is computed as major diameter minus pitch. Where public reference charts disagree on a common drill, the rule value is published instead of a vendor value.
  • SAE ORB dash sizes map to UN/UNF threads tabulated in the tap drill chart on this site; the rule value uses the same d − 1/TPI relation as that family.
  • Start from the thread callout on the drawing, pick the system, then the size. Use the rule or suggested value as the target and the nearest column only as the drill in your hand, and measure the difference before tapping a pressure-carrying thread.

References

Not a substitute for the drawing or the gauge

Pipe threads carry pressure and, in gas service, a safety duty. This chart does not replace the drawing, the thread gauge or the applicable code, and it is not intended for high-pressure or gas applications. Confirm the thread with the specified gauge before assembly.

FAQ

What is the tap drill size for 1/2 NPT?

Two methods are printed for 1/2 NPT: drill 45/64 and tap directly, or drill undersize and ream to 11/16 before tapping. The straight NPSC reference for the same size is 23/32. Most modern NPT charts quote 23/32, which is the straight column, so a chart you already have may show a step above the direct-drilling value.

Why do NPT tap drill charts disagree with each other?

Because they answer different questions. H28 Table 7.2 prints three columns: drilling with a reamer, drilling without one, and the straight NPSC size. Charts that do not say which column they use usually reproduce the straight value. This page shows both methods as tabs and the straight column beside them so the numbers can be compared rather than argued about.

What is the tap drill for BSPP G1/2?

Major diameter minus pitch gives 19.14 mm, and the nearest standard metric drill is 19 mm. Public reference charts quote different common drills for several BSPP sizes, so this table gives the computed value and the nearest drill instead of picking one of them.

Can I use an NPT fitting in a BSPP port?

No. NPT is a 60° tapered thread that seals on the threads; BSPP is a 55° parallel thread that seals on a washer or O-ring. The threads per inch differ at most nominal sizes, and forcing one into the other damages both. Match the port thread named on the drawing.