ENGINEERING TOOL

1-1/4" Bolt Torque Chart (SAE Grades)

Tightening torque ranges (min–typical–max) for 1-1/4" bolts in SAE J429 Grade 2, 5 and 8, across five friction states — UNC 7 TPI plus the fine-thread series. K-factor method, with the metric comparison on the same page.

Other inch sizes

Nearest metric size: M33 M33 →

Full PDF

Download the full PDF (M6–M36, all sizes)

Printable chart covering every size in this family — click to download the PDF directly.

UNC Torque by Grade and Friction State

UNC 7 TPI. Tensile stress area At = 625 mm², per the ASME B1.1 formula. Target preload = 75% of the SAE J429 proof stress × At.

Quick answer: 1-1/4"-7 Grade 5 · electro zinc ≈ 1291 N·m (952 ft·lb); other grades and friction states below.

GradeProof (MPa)Preload (kN)Dry / Black
K 0.18–0.22 · N·m
Electro Zinc
K 0.15–0.2 · N·m
Hot-Dip Galv.
K 0.18–0.25 · N·m
Oiled
K 0.12–0.15 · N·m
Wax / PTFE / Anti-seize
K 0.08–0.12 · N·m
Grade 2228106.7677
610–745
576
508–677
745
610–847
440
406–508
339
271–406
Grade 5510239.31519
1367–1671
1291
1139–1519
1671
1367–1899
988
912–1139
760
608–912
Grade 88273882464
2217–2710
2094
1848–2464
2710
2217–3080
1601
1478–1848
1232
985–1478

Cell shows the typical value; the small line below is the range (min–max).

References

UNF Fine-Thread Torque

1-1/4"-12 UNF: same nominal diameter, finer thread, so the tensile stress area is larger — At = 692 mm² against 625 mm² for the coarse thread — and the torque is higher at the same grade and friction state.

GradeProof (MPa)Preload (kN)Dry / Black
K 0.18–0.22 · N·m
Electro Zinc
K 0.15–0.2 · N·m
Hot-Dip Galv.
K 0.18–0.25 · N·m
Oiled
K 0.12–0.15 · N·m
Wax / PTFE / Anti-seize
K 0.08–0.12 · N·m
Grade 2228118.1750
675–825
638
563–750
825
675–938
488
450–563
375
300–450
Grade 5510264.91682
1514–1850
1430
1262–1682
1850
1514–2103
1093
1009–1262
841
673–1009
Grade 8827429.52728
2455–3000
2318
2046–2728
3000
2455–3409
1773
1637–2046
1364
1091–1637

Cell shows the typical value; the small line below is the range (min–max).

75% vs 90% of Proof Stress

Same grade, same friction state (electro zinc, K 0.15–0.20): the standard level targets 75% of the proof stress — reusable and re-torqueable — while the yield level targets 90%, which sits close to yield and is a one-time setting.

Grade75% proof (reusable)
N·m
90% proof (near yield)
N·m
Grade 2576691
Grade 512911550
Grade 820942513

Use the 75% level for joints that will be disassembled or re-torqued, and the 90% level only where the joint is permanent and the assembly method is controlled. These are percentages of the SAE J429 proof stress, not of the yield strength.

Inch ↔ Metric and SAE ↔ ISO

Order-of-magnitude comparison only, not equivalence — the two systems specify different diameters and thread forms, so torque values must not be carried from one column to the other.

Inch (UNC)Nearest metric
1/4"M6
5/16"M8
3/8"M10
7/16"M12
1/2"M12
9/16"M14
5/8"M16
3/4"M20
7/8"M22
1"M24
1-1/8"M30
1-1/4"M33
1-1/2"M36
2"

SAE Grade ↔ ISO Property Class

SAE J429Approx. ISO 898-1
Grade 24.8
Grade 58.8
Grade 810.9

Approximate only: the proof stresses are not equal even where the strength bands line up (Grade 5 sits near ISO 8.8, but the two standards publish different proof values).

Basis of Calculation & Sources

T = K · d · F: K is the nut factor, d the nominal diameter and F the target preload = SAE J429 proof stress × tensile stress area × 75% (standard level) or 90% (yield level). The stress area follows At = π/4·(d − 0.9743/n)² (ASME B1.1), which for 1-1/4"-7 gives At = 625 mm². Proof stresses are the published SAE J429 values, which step down by nominal diameter tier. K follows published empirical ranges per friction state (Machinery's Handbook); the grease/MoS₂ band (K≈0.11) nearly overlaps anti-seize and is available in the calculator instead of a separate column.

Boundary: this is a simplified K-factor estimate, not a full VDI 2230 analysis (joint resilience, embedment and assembly method are not modelled). Friction is the dominant variable — no single torque value exists for a size without its friction state. Production joints follow the design specification or the manufacturer's torque table.

FAQ

What is the tightening torque for a 1-1/4"-7 Grade 5 bolt?

It depends on the friction state (typical values at 75% of proof stress): dry/black ≈ 1519 N·m, electro zinc ≈ 1291 N·m, hot-dip galvanized ≈ 1671 N·m, oiled ≈ 988 N·m, anti-seize ≈ 760 N·m. Ranges are in the table above — no single torque value exists without its friction state.

Why do UNC and UNF of the same 1-1/4" take different torque?

Because the stress area differs: 1-1/4"-7 UNC has At = 625 mm² while 1-1/4"-12 UNF has At = 692 mm². A finer thread leaves more metal at the minor diameter, so the same grade can be preloaded higher. The UNF table above is calculated independently, not scaled from UNC.

What is the target preload for a 1-1/4" bolt?

At 75% of the SAE J429 proof stress: Grade 2 ≈ 106.7 kN, Grade 5 ≈ 239.3 kN, Grade 8 ≈ 388 kN. Proof stress steps down above each grade's diameter tier (Grade 2 above 3/4", Grade 5 above 1", Grade 8 above 1-1/2"), so preload does not scale linearly with grade on the larger sizes.

What basis are these torque values calculated on?

The K-factor method T = K·d·F, with F = 75% (or 90%) of the SAE J429 proof stress × tensile stress area, and At = π/4·(d − 0.9743/n)² per ASME B1.1. Estimated values, not assembly instructions — run a full VDI 2230 analysis for critical joints.

Related References

Disclaimer: This chart is an engineering estimation for selection and budgeting only. It does not constitute assembly instructions or acceptance criteria.