This page is about the bolt that carries a rooftop solar mounting system down to the structure: the sizes M8 to M12, the accessory that goes with each size, and the supply lengths. It is not a roof-system design. Hole sizes, embedment depth and tightening values are set per project, and they are given here as rules, not as tabulated numbers. For the surrounding fastener data, the bolt size chart covers hex bolts, the torque charts cover tightening values, and the nut and washer charts cover those parts.

Answers first

Nominal diameter d

10mm

source

Machine-thread pitch P

1.5mm

source

Minimum exposed machine thread

10mm

calculated

Flange nut s (across flats)

15

supply dimension

Flange nut k (height)

10

supply dimension

Flange nut dc (flange diameter)

21.8

supply dimension

Bonded washer bore floor

10

calculated · by drawing

Supply lengths

100, 150, 200, 250mm

supply programme

Nominal and supply dimensions for selection, not tolerances. The flange nut is a supply dimension. The washer figure is a bore floor: the actual bore comes from the drawing.

M10 solar hanger bolt: nominal diameter 10 mm, coarse machine-thread pitch 1.5 mm, flange nut 15 / 10 / 21.8 mm across flats / height / flange diameter, bonded washer bore at least 10 mm, and 4 supply lengths — 100, 150, 200, 250 mm.

Full PDF

Download the full PDF (M8–M12, all sizes)

Printable chart covering every size in this family — enter your email to get it.

Wood purlin or steel purlin: which end the bolt needs

A rooftop system is fastened to a purlin through the roof covering. Which end the bolt carries is decided by the purlin, not by the roof sheet. Timber takes a wood thread; steel takes a self-drilling point. The two are not interchangeable in service.

VariantThread form at the embedded endPre-drilled holeWhat the supplier needs from youWhat happens if the two are mixed up
Wood thread (lag) endA coarse wood thread cut into the end of the bolt; the bolt forms its own thread in the timber as it is driven.Usually none, but the pilot hole diameter is a drawing value for the specific bolt: too small and the timber splits, too large and the withdrawal capacity is lost. It is not tabulated on this page.Timber species and grade, purlin width and thickness, and the roof build-up thickness measured on the drawing.A self-drilling point has no thread engagement in timber: it does not hold, and the fixing pulls out under wind uplift.
Self-drilling endA drilling point with a thread behind it; the point drills its own hole in the steel and the thread forms in the same pass.None. The point drills through the sheeting and the purlin, so the purlin thickness has to fall inside the capacity range stated for that point.Purlin material and thickness, the number and thickness of the sheeting layers, and the roof build-up thickness.A wood thread cannot be driven into a steel purlin: the end does not drill, and the thread strips without forming.

The two accessories: flange nut and bonded washer

Every size in this series is supplied with a flange nut and a bonded washer. The nut dimensions are read from the flange-nut dimension source; the washer column gives the floor below which the washer will not pass the machine-thread section.

SizeFlange nut s / k / dc (mm)Bonded washer bore (min, mm)Bonded washer outside diameter and thickness
M813 / 8 / 17.9≥8By drawing — non-standard part
M1015 / 10 / 21.8≥10By drawing — non-standard part
M1218 / 12 / 26≥12By drawing — non-standard part

The flange-nut values are supply dimensions for the parts this series is supplied with. No standard number is printed for them on this page: the column is a supply calibre, and a standard's own dimension table should be read from that standard's own document.

The bonded washer is a non-standard part. Its outside diameter and thickness are not tabulated here, because the seal has to match the sheet profile and the hole in it; they come from the drawing and the batch inspection report for the part actually supplied.

Read from the sources: nominal diameter, coarse pitch, and the three flange-nut dimensions. Calculated here: the bonded-washer bore floor (the bore must pass the machine-thread section, so the floor is the nominal diameter) and the exposure floor (the flange nut is fully engaged when the thread runs through its whole height, so the floor is the nut height k).

Supply lengths for M10

One row per supply length, on the same columns as the chart. The last column shows how much length is left for the roof build-up and the embedded section when the exposed machine thread is only as long as the minimum.

Total length (mm)Nominal dia d (mm)Machine-thread pitch P (mm)Flange nut s (mm)Flange nut k (mm)Flange nut dc (mm)Bonded washer bore (min, mm)Left for roof build-up + embedded section (mm)
100101.5151021.8≥1090
150101.5151021.8≥10140
200101.5151021.8≥10190
250101.5151021.8≥10240

The total lengths are the lengths this series is supplied in. They are not a standard length series: the hanger bolt is a non-standard part made to drawing, so the section lengths are confirmed per order on the drawing. The last column assumes the exposed machine thread is only as long as the minimum, so it is what is left for the roof build-up and the embedded section together — not a permitted build-up thickness on its own.

The other sizes in the series

The neighbouring sizes on the same columns, so the step in diameter, coarse pitch and accessory can be read off directly.

SizeNominal dia d (mm)Machine-thread pitch P (mm)Flange nut s (mm)Flange nut k (mm)Flange nut dc (mm)Bonded washer bore (min, mm)
M881.2513817.9≥8
M10101.5151021.8≥10
M12121.75181226≥12

Minimum thread engagement and embedment

How much thread has to be engaged at each end. Only the machine-thread end can be computed from data on this site; the timber and steel ends are set by the drawing, so the rule is given there instead of a number.

Machine-thread end, under the flange nut

A nut is fully engaged when the thread runs through its whole height, so the exposed machine-thread section has to be at least the flange-nut height k of the size: from 8 mm at M8 to 12 mm at M12, as tabulated at the top of this page. Take off more than the minimum only for a bracket plate or an adjustment range, not for engagement.

exposed machine thread ≥ flange-nut height k

Recomputed on this page from the flange-nut dimension source named above: a calculated floor, not a value taken from a standard table.

Timber purlin — wood-thread end

Engagement in timber is set by how many full threads the wood-thread section forms in the member. That number of threads multiplied by the wood-thread pitch is the embedment the bolt needs, and the pilot hole is sized from the root diameter by the same drawing. Both the pitch and the root diameter belong to the specific bolt and are not tabulated here.

embedment ≥ full threads required × wood-thread pitch

Engineering rule of thumb, not a standard value. The values for a specific part come from the supplier drawing and the batch inspection report.

Steel purlin — self-drilling end

The self-drilling point has to form a full thread in the steel. Because the same point drills the hole and taps it, the capacity is fixed by the point geometry: the member thickness has to fall inside the range stated for that point, and the thread engagement is then the full member thickness.

purlin thickness within the drilling capacity range of the point

Engineering rule of thumb, not a standard value. The capacity range of the point comes from the supplier drawing for that point.

Everything in this section is a selection rule, not a standard value and not a test result. Values for a project are set by the drawing and confirmed by the supplier before installation.

Tightening torque and re-checking on the roof

No tightening torque is tabulated on this page. A ceiling can be recomputed for a bolt whose property class is known, from the friction-factor range published on this site, but the mechanical property values behind the stainless classes are not reproduced here and the supply lengths on this page do not fix a class. Take the class from the drawing, compute from it, and confirm against the supplier's data for the part actually supplied.

T = K × F × d, with K from the friction-factor range on this site

Needs the property class, taken from the drawing or the batch inspection report

A torque value is deliberately not tabulated on this page.

Friction-factor range on the torque chart →

Before ordering: what to measure and what to send

A hanger bolt is quoted by three groups of dimensions. Only one of them is fixed by the bolt itself; the other two come from the roof and from the structure.

  • Roof build-up: from the top of the purlin to the outside face of the covering
  • Exposed machine thread: the bonded washer, the bracket or L-foot, and the flange nut, plus any adjustment range
  • Embedded section: the wood thread in the timber, or the self-drilling point through the steel

Send with the enquiry

  • Size (M8, M10 or M12) and the required total length in millimetres
  • Which end the purlin needs: wood thread for timber, self-drilling for steel, with the member material and thickness
  • Roof build-up thickness, measured from the top of the purlin to the outside face of the covering
  • Bracket or L-foot thickness, and whether the flange nut and bonded washer come with the bolt or separately
  • Finish, part marking and documentation the job requires, and the property class where the drawing fixes one

The flange nut and the bonded washer are supplied as a set with the bolt. Where they are bought separately, take the bore from the table above and the nut dimensions from the same source; where the roof build-up is close to a length step, send the measured thickness and the purlin section rather than choosing between two lengths on the drawing alone.

What this page does not tabulate

Three groups of values are left out on purpose rather than filled in from a supplier catalogue. Each one is listed with its reason, so that a missing number is not mistaken for an oversight.

Wood-thread section: pitch, root diameter and section length

The part is not made to a standard, so there is no standard table for it and no supplier-independent value to quote. The value comes from the drawing for the part.

Bonded washer outside diameter

The part is not made to a standard, so there is no standard table for it and no supplier-independent value to quote. The value comes from the drawing for the part.

Bonded washer thickness

The part is not made to a standard, so there is no standard table for it and no supplier-independent value to quote. The value comes from the drawing for the part.

Pilot hole diameter

The part is not made to a standard, so there is no standard table for it and no supplier-independent value to quote. The value comes from the drawing for the part.

Minimum embedment depth as a number

The data behind it is published by installation-system suppliers and varies by project and product line; the generic derivation is given in the engagement section.

Tightening torque value

The value depends on the mechanical properties of the property class and varies with the class ordered; the method is given in the tightening section.

Going further with M10

Accessories, by standard

Other tool pages

  • Bolt size chart →

    Hex bolt dimensions in the same style: across flats, head height, thread length, by size and by standard.

  • Bolt torque chart →

    Tightening values tabulated by diameter and grade, with the friction-factor range used for the calculation.

  • Hex nut weight chart →

    Hex nuts by size with across-flats and height, and the weight per piece for order quantities.

  • Flat washer weight chart →

    Plain washers by size with outside diameter and thickness, and the weight per piece.

  • Screw size chart →

    Metric machine screws by size with head and drive dimensions, for the parts that go on the bracket side.

Where these numbers come from

The values on this page are read from the thread source and the flange-nut dimension source on this site and recalculated here; the supply lengths are this series' own supply programme.

What is covered

Sizes M8 to M12 — 3 sizes — across the 4 supply lengths 100, 150, 200, 250 mm: 12 rows, one per size and length, with 3 size pages of their own. Over this range the coarse pitch runs from 1.25 mm to 1.75 mm and the flange-nut height from 8 mm to 12 mm.

What is not covered

Sizes below M8 and above M12 are not part of this series, and no values are supplied for them here. The 6 values listed in the section above are left out rather than filled in from a supplier listing, and the installation-system vendors' technical data behind the embedment question are recorded by name only — no values are taken from them.

Calibre of the values: Nominal (basic) dimensions and supply dimensions, for selection and purchasing. They are not tolerances, not limits of size and not interchangeability values. The supply lengths are a supply programme, not a standard series.

Coverage: This is one of the 3 sizes in the series that have a page of their own; the full table across every size and supply length is on the size chart.

Sources for this size

Values on this page are taken from the sources listed and computed here as described; the sources' own typography and additional columns are not reproduced.

Send the size list, get the hanger bolts quoted

If you have the sizes, the purlin type and the roof build-up on a drawing or a picking list, send them across and we will come back with the parts that answer them: the size and total length, the accessory set, and the documents the job needs. We work as a manufacturing and export company with both our own production and an integrated supply network, so a mixed list is read as one specification and comes back as one quotation.

  • Sizes and total lengths, or the roof build-up and purlin dimensions to work them out
  • Which end the purlins need, with the member material and thickness
  • Accessory set required: flange nut and bonded washer, and any bracket plate
  • Finish, property class, part marking and the documents the job needs

Cite this chart

YAXIIO. M10 solar hanger bolt. https://www.yaxiio.com/en/tools/solar-hanger-bolt-chart/m10 (accessed 2026-10-29).

Free to cite and embed — attribution required: “YAXIIO” + a link to this page.

Frequently asked questions

What is the M10 solar hanger bolt?

A M10 hanger bolt has a nominal machine-thread diameter of 10 mm and a coarse pitch of 1.5 mm. It is supplied with a flange nut of 15 mm across flats, 10 mm high and 21.8 mm across the flange, and with a bonded washer whose bore is at least 10 mm.

Which lengths does M10 come in?

Total lengths of 100, 150, 200, 250 mm — 4 lengths. The last column of the table above shows how much is left for the roof build-up and the embedded section when the exposed machine thread is only as long as the minimum.

How much machine thread has to be exposed for the flange nut on M10?

At least 10 mm, which is the height of the flange nut: the nut is fully engaged when the thread runs through its whole height. Anything beyond that is for a bracket plate or an adjustment range, not for engagement.

Which bonded washer goes on M10?

One whose bore is at least 10 mm, so that it passes the machine-thread section. Outside diameter and thickness are not tabulated: they come from the drawing for the part, because the seal has to match the sheet profile and the hole in it.